ABB 33 KV RING MAIN UNIT (RMU)

Request Callback

₹ 950000 / Piece Get Latest Price

Product Brochure
Rated Voltage33 kV
Ambient Temperature-25.....40Deg C
Rated Current630 Amp.
No. Of Poles3 Pole
Degree Of ProtectionIP54
Country of OriginMade in India
33 KV, 630A, 21kA/3Sec Non-Extensible, Outdoor Type Ring Main Unit Compact switchgear consisting of One Nos. 630A fixed Manual, Vacuum Circuit Breaker in SF6 insulated stainless steel enclosure with microprocessor based ABB make numerical over current and earth fault relay (IDMTL + Inst.), LV class Protection Ring Core CT for protection and arrangement for connecting incoming cable & outgoing cable

11 kV Ring Main Unit

Request Callback

₹ 220000.00 / Unit Get Latest Price

Product Brochure
Rated Voltage11 kV
BrandSchneider
MaterialMild Steel
Warranty1 Year
Frequency50 Hz
Current630 A

An 11 kV Ring Main Unit (RMU) is a compact, sealed, and fully enclosed switchgear unit designed for medium voltage power distribution networks, typically operating at 11 kilovolts (kV). It plays a crucial role in ensuring uninterrupted power supply and facilitates maintenance and fault isolation in urban and industrial electrical networks.

11 kV Schneider Ring Main Unit

Request Callback

Get Latest Price

Product Brochure
Rated Voltage11 kV
IP RatingIP55
Usage/ApplicationIndustrial
BrandSchneider
Rated Current630kVA
Frequency50 Hz
A Ring Main Unit (RMU) is a metal-enclosed, factory-assembled medium-voltage switchgear designed for ring-type distribution networks (typically 7.2–36 kV)

ABB Make 11 KV RING MAIN UNIT (RMU)

Request Callback

₹ 250000 / Piece Get Latest Price

Product Brochure
Degree Of ProtectionIP54
No. Of Poles3 POLE
Usage/ApplicationOutdoor
BrandABB
MaterialCOPPER BUS BAR
Rated Short Time Current21kA / 3 Sec
ColorRAL 7035
Size/Dimension1210 x 755 x 1540 mm
FinishingIEC 62271-200
Rated Insulation Level28/75 KV
Warranty1 YEAR
Weight400 KGS.
Ambient air temperature for operation-25.....40Deg C

Minimum order quantity: 1 Piece

11kV, 630A, 21kA/3Sec Non-Extensible, Outdoor Type Ring Main Unit Compact switchgear consisting of One Nos. 630A fixed Manual, Vacuum Circuit Breaker in SF6 insulated stainless steel enclosure with microprocessor based ABB make numerical over current and earth fault relay (IDMTL + Inst.), LV class Protection Ring Core CT for protection and arrangement for connecting incoming cable & outgoing cable

33 kV Schneider Ring Main Unit

Request Callback

₹ 250000 / Unit Get Latest Price

Product Brochure
Rated Voltage33kV
Degree Of ProtectionIP54 Indoor And IP65 Outdoor
No. Of Poles3
BrandSchneider
MaterialMS
Frequency60 Hz

ABB / Siemens / Schneider / Crompton Make 11kV | 22kV | 33kV Ring Main Unit (RMU)

Product Description:
We offer high-performance Ring Main Units (RMUs) in 11kV, 22kV, and 33kV variants sourced from globally trusted brands — ABB, Siemens, Schneider Electric, and Crompton. These RMUs are ideal for medium-voltage power distribution and ensure operational safety, reliability, and compact design, making them suitable for both indoor and outdoor substation applications.

Key Features:

  • Voltage Ratings: 11kV / 22kV / 33kV

  • Gas Insulated / Air Insulated options

  • Compact and modular design

  • Indoor and outdoor variants available

  • High fault withstand capacity

  • Low maintenance and long service life

  • Compatible with SCADA and remote monitoring systems

  • Factory-tested for guaranteed performance

Applications:

  • Industrial Plants

  • Residential & Commercial Complexes

  • Infrastructure Projects

  • Utility Distribution Networks

  • Renewable Energy Installations

Brands Available:
✅ ABB
✅ Siemens
✅ Schneider Electric
✅ Crompton Greaves

Why Choose Us:

  • Authorised Channel Partner – ABB

  • Over 20 years of industry experience

  • Trusted by leading clients like NTPC, Patanjali, DLF, Maruti, DRDO, and more

  • Ready stock and fast delivery across India

  • Expert technical support and after-sales service

 

Contact Us Today for Bulk Orders or Custom Specifications.

12 kV Ring Main Unit

Request Callback

₹ 295000.00 / Unit Get Latest Price

Product Brochure
Rated Voltage12kV
No. Of Poles1
MaterialMild Steel
Warranty1 Year
Frequency60 Hz
Power SourceElectric

A Ring Main Unit is a pre-engineered, enclosed switchgear assembly used in ring‑type medium‑voltage systems (typically 7.2–36 kV) to manage feeders and transformer connections . The 33 kV version operates on higher distribution voltages.

11 kV Schneider Ring Main Unit

Request Callback

₹ 250000 / Unit Get Latest Price

Product Brochure
Rated Voltage11 kV
Usage/ApplicationIndustrial
BrandSchneider
IP RatingIP55
Rated Current630 kVA
Frequency50 Hz
A Ring Main Unit is a compact, metal-clad switchgear designed for medium-voltage (typically 7.2–36 kV) distribution networks. It houses all necessary switching and protection elements—switch-disconnectors or vacuum circuit breakers (VCB), earthing switches, and possibly fuses or relays—inside a single gas (SF₆) or air-insulated sealed unit

Siemens 11kV RMU RRL Outdoor 630A 21kA SF6 Ring Main Unit (2LBS + 1VCB)

Request Callback

Get Latest Price

Rated Voltage11 kV
Number Of Ways3 way
Insulation MediumSF6
Installation TypeOutdoor
Number Of Poles3
Frequency50 Hz
Ip RatingIP54
Rated Current630 A
BrandSiemens

We offer Siemens make 11 kV SF₆ gas insulated Ring Main Unit (RMU), type RRL, designed for reliable and safe medium voltage power distribution in industrial, commercial, and utility applications. Built on Siemens’ proven 8DJH platform, this RMU ensures compact design, operational safety, and long service life under demanding site conditions.

The unit is configured as a 3-way non-extensible outdoor RMU, comprising 2 load break switch (LBS) feeders and 1 vacuum circuit breaker (VCB) feeder, suitable for ring network and radial distribution systems.

Key Technical Features
  • Rated Voltage: 12 kV (11 kV system)
  • Rated Current: 630 A
  • Short Circuit Withstand: 21 kA for 3 seconds
  • Frequency: 50 Hz
  • Configuration: 2 × LBS + 1 × VCB
  • Operation: Manually operated switches and breaker
  • Insulation Medium: SF₆ gas insulated system
  • Enclosure: Outdoor type with IP54 protection
  • Busbar: Copper busbars housed in SF₆ gas
  • Protection: VCB feeder equipped with self-powered current protection relay
  • CT Ratio: 200/1 A (typical protection core)
  • Switching Arrangement: 3-position disconnector with integrated earthing switch
  • Indication: Voltage Presence Indication System (VPIS)
  • Cable Entry: Bottom entry, suitable for standard HT cable terminations
Applications
  • Industrial power distribution systems
  • Commercial complexes and infrastructure projects
  • Utility substations and ring networks
  • Renewable energy evacuation systems
Advantages
  • Compact, space-saving design
  • High operational safety with enclosed SF₆ system
  • Maintenance-friendly and long service life
  • Suitable for outdoor installation
  • Reliable protection with VCB + relay combination
  • Proven Siemens engineering and quality

LUCY Make 11kV 630A 1 way Ring Main Unit (RMU)-VCE

Request Callback

Get Latest Price

Rated Voltage11 kV
Number Of Panels1 Way
Insulation MediumSF6 Gas
Rated Current630 A
Breaker TypeVacuum Circuit
Installation TypeOutdoor
Protection TypeRelay Protection
Degree Of ProtectionIP54
StandardsIEC 62271-200

11 kV SF₆ gas insulated Ring Main Unit (RMU) with Vacuum Circuit Breaker (VCB) module, suitable for medium voltage distribution networks and compact substations. The unit is designed for reliable switching, protection, and isolation of transformer feeders and outgoing lines.

The RMU consists of a single VCB-based tee-off module with load break isolator and earthing switch, ensuring safe operation through mechanical interlocks and clear position indication. The switching elements are enclosed in a sealed SF₆ gas insulated tank, providing maintenance-free operation and long service life.

The unit is extensible type, allowing future expansion of the network without major modification. It is suitable for outdoor installation with robust enclosure and cable termination arrangement.

Protection is provided through self-powered overcurrent and earth fault relay along with protection CTs, ensuring effective fault detection and tripping.

Complete RMU supplied with VCB, isolator, earthing switch, protection system, and accessories, as per standard design / customer requirement.

Siemens make 11 kV SF6 gas insulated Ring Main Unit (RMU), type RLL (1LBS+2VCB)

Request Callback

Get Latest Price

Rated Voltage11 kV
Number Of Ways3 way
Insulation MediumSF6
Installation TypeOutdoor
Number Of Poles3
Frequency50 Hz
Ip RatingIP54
Rated Current630 A
BrandSiemens
Siemens make 11 kV SF₆ gas insulated Ring Main Unit (RMU), type RLL, outdoor, non-extensible, manually operated, rated voltage 12 kV, rated current 630 A, rated short-time withstand current 21 kA for 3 seconds, 50 Hz system, comprising 1 No. load break switch feeder and 2 Nos. vacuum circuit breaker feeders, complete with three-position disconnector and earthing switch arrangements as applicable, voltage indication system (VPIS), stainless steel SF₆ gas tank, suitable for outdoor installation, copper busbars housed in SF₆ gas, VCB feeders provided with protection relays as applicable and associated current transformers (ratio as per drawing), internal arc classification up to 21 kA, bottom cable entry, complete unit as single transport section, as per drawing / documents enclosed.

Abb 11Kv 630A 21Ka Outdoor Sf6 Rmu CVC Type (2 Lbs + 1 Vcb)

Request Callback

Get Latest Price

Rated Voltage11 kV
Insulation MediumSF6 Gas
Installation TypeOutdoor
Rated Current630 A
Configuration3 Way
Degree Of ProtectionIP54
ABB make 11 kV class SF₆ gas insulated Ring Main Unit (RMU), type CVC, outdoor, non-extensible, manually operated, rated voltage 12 kV, rated current 630 A, rated short circuit withstand current 21 kA for 3 seconds, frequency 50 Hz, comprising 2 Nos. load break switch feeders and 1 No. vacuum circuit breaker feeder, complete with earthing switch, disconnector arrangements, and capacitive voltage presence indication system (VPIS). The RMU is provided with a sealed stainless steel SF₆ gas tank (IP67) and outdoor enclosure (IP54), suitable for reliable operation under outdoor conditions. The VCB feeder is equipped with numerical overcurrent and earth fault protection relay along with current transformers of ratio 200/1 A. The unit is designed for medium voltage distribution applications and conforms to IEC 62271-200 standards.

ABB 11kV RMU CVV SafeRing XT (1 LBS + 2 VCB feeders)

Request Callback

Get Latest Price

Rated Voltage11 kv
Number Of Poles3
Insulation MediumSF6
Installation TypeOutdoor
Number Of Ways3
Ip RatingIP54
BrandABB
Rated Current630 a

ABB Make 11 kV Outdoor RMU (Ring Main Unit) – Type CVV, SafeRing XT

ABB make 11 kV class SF₆ gas insulated Ring Main Unit (RMU), type CVV, outdoor, non-extensible, manually operated, suitable for medium voltage distribution applications, rated voltage 12 kV, rated current 630 A, and rated short circuit withstand current 21 kA for 3 seconds, frequency 50 Hz, designed and manufactured in accordance with IEC 62271-200.

The RMU comprises 1 No. load break switch feeder (C module) and 2 Nos. vacuum circuit breaker feeders (V modules) (i.e., 1 LBS + 2 VCB feeders), complete with disconnector and earthing switch arrangements, and capacitive voltage presence indication system (VPIS) for safe operation.

The unit is provided with a sealed stainless steel SF₆ gas tank (IP67 protection) and outdoor enclosure with IP54 degree of protection, ensuring reliable performance in outdoor conditions.

VCB feeders are equipped with numerical overcurrent and earth fault protection relays, along with protection CTs of ratio 200/1 A, Class 5P10, 2.5 VA. CT ratio can be upgraded to 400/1 A if required. Metering provision can also be offered on request.

The RMU is suitable for front cable termination with bottom cable entry, supporting cable sizes up to 3C x 300 sq.mm, and includes standard compartments such as cable compartment, LV compartment, and mechanism section.

Additional features include:

  • Compact SF₆ insulated design with low gas leakage (<0.1% per annum)
  • Nominal gas pressure approx. 1.3 bar at 20°C
  • Copper busbar system inside sealed tank
  • Ambient temperature range: -25°C to +40°C
  • Suitable for installation up to 1000 m altitude
  • Outdoor powder-coated enclosure (RAL 7035)
  • Provision for external earthing

 

Extensible and motorised variants can also be provided if required, subject to customer specification.

ABB 11 kV 630A Outdoor 1 Way RMU 1 (VD Type), 21 kA, Manual, SF6 Insulated

Request Callback

Get Latest Price

Rated Voltage11 kv
Number Of Poles3
Insulation MediumSF6
Installation TypeOutdoor
Number Of Ways1
Rated Current630 a
Ip RatingIP54
BrandABB
MaterialMild Steel

ABB make 11 kV class SF₆ gas insulated Ring Main Unit (RMU), SafeLink CB type VD, outdoor, non-extensible, manually operated, rated voltage 12 kV, rated current 630 A, rated short circuit withstand current 21 kA for 3 seconds, frequency 50 Hz, complete unit as per manufacturer’s standard.The configuration incorporates a V Module (Vacuum Circuit Breaker) and a D Module

The RMU is provided with sealed stainless steel SF₆ gas tank, capacitive voltage presence indication system (VPIS), vacuum circuit breaker module with associated protection components, disconnector and earthing switch arrangements as applicable.

Degree of protection: IP54 for enclosure and IP67 for tank.
Power frequency withstand voltage / BIL: 28 kV / 75 kVp.
Nominal gas pressure: approx. 1.2 bar at 20°C.

Suitable for outdoor installation, complete in all respects as per approved drawing and technical document.

ABB Make 11 kV Outdoor RMU (Ring Main Unit) ,Type CCVV, SafeRing XT ( 2 LBS+2 VCB)

Request Callback

Get Latest Price

Rated Voltage11 kv
Number Of Poles3
Insulation MediumSF6
Installation TypeOutdoor
Number Of Ways4
Ip RatingIP54
BrandABB
MaterialMild Steel
Rated Current630 a

ABB make 11 kV class SF₆ gas insulated Ring Main Unit (RMU), type CCVV, outdoor, non-extensible, manually operated, suitable for medium voltage distribution applications, rated voltage 12 kV, rated current 630 A, and rated short circuit withstand current 21 kA for 3 seconds, frequency 50 Hz, designed and manufactured in accordance with IEC 62271-200.

The RMU comprises 2 Nos. load break switch feeders (C modules) and 2 Nos. vacuum circuit breaker feeders (V modules) (i.e., 2 LBS + 2 VCB feeders – 4 way RMU), complete with disconnector and earthing switch arrangements, and capacitive voltage presence indication system (VPIS) for safe operation.

The unit is provided with a sealed stainless steel SF₆ gas tank (IP67 protection) and outdoor enclosure with IP54 degree of protection, ensuring reliable performance under outdoor conditions.

VCB feeders are equipped with numerical overcurrent and earth fault protection relays, along with protection CTs of ratio 200/1 A, Class 5P10, 2.5 VA.
CT ratio can be upgraded to 400/1 A if required. Metering provision can also be provided on request.

The RMU is suitable for front cable termination with bottom cable entry, supporting cable sizes up to 3C x 300 sq.mm, and includes standard compartments such as cable compartment, LV compartment, and mechanism section.

Additional features include:

  • Compact SF₆ insulated design with low gas leakage (<0.1% per annum)
  • Nominal gas pressure approx. 1.3 bar at 20°C
  • Copper busbar system inside sealed tank
  • Ambient temperature range: -25°C to +40°C
  • Suitable for installation up to 1000 m altitude
  • Outdoor powder-coated enclosure (RAL 7035)
  • Provision for external earthing

Extensible and motorised variants can also be provided if required, subject to customer specification.

Lucy 11kV SF6 Ring Main Unit (RMU) 630A 21kA Outdoor 2LBS + 1 VCB

Request Callback

Get Latest Price

Rated Voltage11 kV
Number Of Panels3 Panel
Insulation MediumSF6 Gas
Rated Current630 A
Breaker Type2 LBS + 1 VCB
Installation TypeOutdoor
Configuration3 Way
Protection TypeRelay Protection
Degree Of ProtectionIP54
StandardsIEC 62271-200

11 kV class SF₆ gas insulated Ring Main Unit (RMU), outdoor type, non-extensible, manually operated, designed for reliable medium voltage distribution applications.

The RMU is configured as a 3-way unit comprising 2 load break switch (LBS) feeders and 1 vacuum circuit breaker (VCB) feeder, suitable for ring network applications. The unit is rated 630 A, 21 kA for 3 seconds, 50 Hz, and is equipped with standard switching and earthing arrangements.

The system consists of SF₆ insulated sealed tank construction, ensuring safe and maintenance-minimised operation. The VCB feeder is provided with associated protection and control arrangements as per design, including numerical relay compatibility and protection CT provisions.

The RMU is supplied complete with voltage presence indication system (VPIS), operating mechanism, cable termination arrangements, and internal interconnections, as per approved drawing and bill of material.

The unit is suitable for outdoor installation, with robust enclosure construction and designed for safe operation under standard service conditions.

Lucy Make 11 kV Ring Main Unit (RMU), Type VRN (2LBS + 1VCB)

Request Callback

Get Latest Price

Rated Voltage11 kV
Number Of Panels3 Panel
Insulation MediumSF6 Gas
Rated Current630 A
Installation TypeOutdoor
Configuration3 Way
Degree Of ProtectionIP54

11 kV class SF₆ gas insulated Ring Main Unit (RMU), type VRN, outdoor, non-extensible, manually operated, rated voltage 12 kV, rated current 630 A, rated short circuit withstand current 21 kA for 3 seconds, 50 Hz, comprising 2 Nos. load break switch feeders and 1 No. vacuum circuit breaker feeder, complete with associated isolator and earthing switch arrangements as applicable. The unit is provided with vacuum interrupter, selector switch/off-load isolator, ring cable box with gland plate, T-off cable box with gland plate, and operating mechanism, suitable for outdoor installation. The VCB feeder is equipped with numerical overcurrent and earth fault protection relay (self-powered) and associated current transformers (approx. 100/1 A class, as per design), along with trip coil arrangement. The RMU is fitted with capacitive voltage presence indication system (VPIS), SF₆ gas tank (minimum pressure approx. 0.05 bar), terminal protection boots, and complete control/marshalling arrangement.

Siemens 11 kV SF6 Gas Insulated RMU (RRLL) 2 LBS + 2 VCB, Outdoor, 630A, 21kA

Request Callback

Get Latest Price

Rated Voltage11 kV
Number Of Panels4 Panel
Insulation MediumSF6 Gas
Installation TypeOutdoor
Rated Current630 A
Configuration4 Way
Protection TypeRelay Protection
Degree Of ProtectionIP54
StandardsIEC 62271-100

Siemens make 11 kV class SF₆ gas insulated Ring Main Unit (RMU), type RRLL, suitable for outdoor installation, non-extensible design, rated voltage 12 kV, rated current 630 A, and rated short-time withstand current 21 kA for 3 seconds, suitable for 50 Hz systems.

The RMU is configured with 2 Nos. Load Break Switch (LBS) feeders and 2 Nos. Vacuum Circuit Breaker (VCB) feeders, complete with three-position disconnector and earthing switch arrangements as applicable. The unit is provided with a sealed stainless steel SF₆ gas tank, ensuring high operational reliability and minimal maintenance.

VCB feeders are equipped with numerical overcurrent and earth fault protection relays along with associated current transformers (ratio as per requirement/drawing). The RMU includes voltage presence indication system (VPIS) for safe operation and maintenance.

Designed as a compact, factory-assembled unit, it features copper busbars housed in SF₆ gas, internal arc classification up to 21 kA, and bottom cable entry, making it suitable for industrial and utility distribution networks.

Complete unit supplied as per approved drawing / BOQ / technical documents.

Key Features
  • Siemens make, RRLL configuration
  • 2 LBS + 2 VCB feeders
  • 630 A, 21 kA for 3 sec
  • SF₆ gas insulated, sealed for life tank
  • Outdoor, non-extensible design
  • Numerical protection with CTs (VCB feeders)
  • VPIS for voltage indication
  • Compact, low maintenance solution
Applications
  • Industrial power distribution
  • Utilities & substations
  • Infrastructure & commercial projects

ABB Make Outddor/ Indoor 33 kV SF6 RMU l Type +V

Request Callback

Get Latest Price

Rated Voltage33 kv
Number Of Poles3
Insulation MediumSF6
Installation TypeIndoor/ Outdoor
Number Of Ways1
PhaseThree Phase
Ip RatingIP54
BrandABB
MaterialMild Steel
Rated Current630 a

33 kV class SF₆ gas insulated Ring Main Unit (RMU), type +V, suitable for indoor or outdoor installation, available in extensible or non-extensible configurations as per requirement. The unit is rated up to 36 kV, 630 A, and short-time withstand current up to 25 kA for 1 second, suitable for 50 Hz systems.

The RMU comprises VCB feeder module (Vacuum Circuit Breaker only), complete with disconnector and earthing switch arrangement, voltage presence indication system (VPIS), and associated current transformers for protection.

The unit features a sealed stainless steel SF₆ gas tank with copper busbars, ensuring high operational reliability, safety, and minimal maintenance. Designed for utility and industrial applications, it is housed in a robust enclosure suitable for outdoor/indoor environments with a high degree of protection.

 

Provision can be made for metering and integration with SCADA / FRTU for remote monitoring and control, depending on project requirements. The equipment can be customised as per drawing, BOQ, or end-user specifications.

ABB 11 kV Outdoor RING MAIN UNIT 630A 21kA CCV (2 LBS + 1 VCB)

Request Callback

Get Latest Price

Rated Voltage11 kv
Number Of Poles3
Insulation MediumSF6
Installation TypeOutdoor
Number Of Ways3
Ip RatingIP54
BrandABB
MaterialMild Steel
Rated Current630 a
11 kV class SF₆ gas insulated Ring Main Unit (RMU), outdoor type, non-extensible, manually operated, rated voltage 12 kV, rated current 630 A, rated short circuit withstand current 21 kA for 3 seconds, frequency 50 Hz, configuration type CCV comprising 2 Nos. manually operated load break switch feeders and 1 No. manually operated vacuum circuit breaker feeder, complete with earthing switch and disconnector arrangements as applicable, capacitive voltage presence indication system (VPIS), sealed stainless steel SF₆ gas tank, suitable for outdoor installation, VCB feeder provided with numerical overcurrent and earth fault protection relay and associated current transformers

Rmu Ring Main Unit

Request Callback

Get Latest Price

Product Brochure

Ring Main Unit

Request Callback

Get Latest Price

Product Brochure

Abb Ring Main Unit 11 Kv

Request Callback

Get Latest Price

Product Brochure

Ring Main Unit Rmu

Request Callback

Get Latest Price

Product Brochure

Siemens Ring Main Unit

    Request Callback

    Get Latest Price

    Product Brochure

    Crompton Greaves Ring Main Unit

      Request Callback

      Get Latest Price

      Product Brochure
      X

      Contact Us

      Puja Arora (CEO)
      Industrial Control System
      1853/9,Surya Bazar, Bhagirath Palace, Delhi
      New Delhi - 110006, Delhi, India

      Get Directions
      Send Email
      Share: